Ticked
All checklists

solid test

Export PDF

SRM Static Fire Checklist v1 · Started by Randi · 2026/11/10 04:07

8 / 39 done

Snowdon Consulting · Solid rocket motor testing. Matches the SRM Hazard Mitigation Plan and Emergency Response Plan (checklist version 6 Nov 2026).

Every box must be ticked before firing. Save the record as a PDF and post it in the Health & Safety chat, once before firing and once after the test. The RSO keeps final go/no-go.

1. Test details5/6

Test date recorded✓ Randi · 2026/11/10 04:07
Test report no. recordede.g. PTR-012✓ Randi · 2026/11/10 04:07
Test site / stand recordedField name or address.✓ Randi · 2026/11/10 04:07
Motor / grain no. recordedBatch and grain #.unticked by Caelen · 2026/11/10 04:19
Range Safety Officer named✓ Randi · 2026/11/11 04:35
Checklist completer named✓ Randi · 2026/11/11 04:35

2. Pre-test go/no-go3/23

Site and weather0/5

FENZ fire season checked (checkitsalright.nz); permit held if required
Wind within limits (≤ 20 km/h) and not blowing toward trees
Firebreak cleared evenly all round the stand
Grass wetted with the ute tank and pump; ute parked upwind, pump primed
Nothing overhanging the stand (branches, wires)

Stand and enclosure3/3

Enclosure inspected: no cracks or loose fasteners; top and bottom vents clear✓ Randi · 2026/11/10 04:08
Motor restraint and ground anchors checked✓ Randi · 2026/11/10 04:08
Blast plate / deflector in place over sand or gravel bed✓ Randi · 2026/11/10 04:08

Equipment and people0/10

Extinguishers, beaters, water and first aid kit at the firing point
Phone signal confirmed; 111 caller and site address / GPS assigned
All roles filled and briefed
RSO
Test Conductor
2 × Fire Watch
First Aider
Marshal
Everyone behind the safety line; spectators and animals clear
Hearing and eye protection on

Firing system0/3

Firing system safe; key held by the RSO
Igniter installed last, phones off near the pad
Continuity checked from the safety line

Record0/2

Pre-test record saved as PDF
Pre-test record posted in the Health & Safety chat

3. Fire0/1

HOLD · DO NOT ARM until the pre-test checklist is complete and the record is posted to the H&S chat. The RSO gives the final go. If anything changes on the range, call HOLD.

RSO final go given

4. Post-test0/9

Outcome recordedNominal burn · Anomaly (no CATO) · Misfire / hang-fire · CATO · Aborted before firing
Motor burned out, or hang-fire wait (min. 5 min) observed; key out before approach
Area swept for spot fires and fragments
Burnt ground and firebreak wetted down
Fire Watch kept for 30 minutes after the last firing
Hardware made safe; unused motors and igniters stored separately
Results and anomalies recorded in the Propellant Test Report (sections 8–9)

For a CATO, misfire or anomaly: follow the Emergency Response Plan (E1 for CATO, E5 for misfire) and log it in Test Report section 9.

Record0/2

Post-test record saved as PDF
Post-test record posted in the Health & Safety chat
Activity10
  1. 2026/11/11 04:35Randi ticked Checklist completer named
  2. 2026/11/11 04:35Randi ticked Range Safety Officer named
  3. 2026/11/10 04:19Caelen unticked Motor / grain no. recorded
  4. 2026/11/10 04:19Caelen ticked Motor / grain no. recorded
  5. 2026/11/10 04:08Randi ticked Blast plate / deflector in place over sand or gravel bed
  6. 2026/11/10 04:08Randi ticked Enclosure inspected: no cracks or loose fasteners; top and bottom vents clear
  7. 2026/11/10 04:08Randi ticked Motor restraint and ground anchors checked
  8. 2026/11/10 04:07Randi ticked Test site / stand recorded
  9. 2026/11/10 04:07Randi ticked Test report no. recorded
  10. 2026/11/10 04:07Randi ticked Test date recorded